The
installation of the Ocean Cool requires no refrigeration skills. Each
Ocean Cool airconditioner comes precharged and factory tested, ready to
bolt down and connect up for immediate operation. The safety arrangements
provide refrigerant circuit protection by means of failsafe shutdown in
the event of low or high refrigerant pressure caused by lack of air flow
or lack of seawater flow, as experienced by clogged seawater inlet strainers.
This is also one of the main causes for premature compressor burnout of
marine refrigeration or airconditioning equipment. Sufficiently sized
seawater strainers are essential for reliable performance of the equipment.
HFL can provide the complete package including the grilles, ductwork,
Y pieces, return air apertures, transitions, rings, etc to facilitate
easy installation. The accessories also allow for the climate control
of two cabins from one single airconditioner. Two Ocean Cool units can
be powered by one seawater pump provided a relay box is being used.
The
Ocean Cool airconditioner is to be powered via a battery with the power
source either from a battery charger connected to shore supply or from
the engine driven alternator when the propulsion unit is running or better
still from an HFL diesel charger, available at 12 or 24 volts. The HFL
"Traveller" comes with a rating of 12 volt 100amps max or 24 volt 50amps
max output.
A
battery monitor should be installed to alert of low battery voltage. Even
better would be the use of a complete battery monitoring system, such
as the SALT battery monitor. The low voltage battery signal can be used
to automatically start the HFL "Traveller" and ensure continuous operation
of the airconditioner.
HFL recommend battery sizes of at least 160Ahrs (2x80Ahrs) at 12 volt
and the same for a 24 volt system. If the battery voltage is too low or
the battery size too small the equipment will perform unsatisfactorily.
An operating range of Dt can be expected between 10-15°C at a seawater
temperature range up to 25°C and an ambient air of up to 40°C.
|
|
|
MODEL
|
BTU/h
|
Kcal/h
|
W/h
|
Dimensions
Inches----------------- mm
|
Amp
12V 24V
|
Watts
|
Duct
Inches---- mm
|
kg
|
|
HSD6012
|
6000
|
1500
|
1350
|
17½x14x11½
|
440x360x290
|
44
|
|
528
|
5"
|
125
|
32
|
|
HSD7024
|
7000
|
1750
|
1575
|
18x14x11½
|
460x360x290
|
|
28
|
670
|
5"
|
125
|
35
|
|
|